Monessen Hearth HDV500NV/PV Manual De Usuario

Descargar
Página de 64
56D3048
35
HDV Series Direct Vent Gas Fireplace
COMMAND
CENTER
4-AA BATTERY
COMPARTMENT
MASTER
SWTICH
TO JUNCTION BOX
IN FIREPLACE
CONVERSION
NG/LP
RF RECEIVER
ON/OFF BUTTON
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
CONNECTOR
PIN TO CONTROL BOX
OPTIONAL
AC BOX
{
{
{
OPTIONAL
BLOWER
OPTIONAL
LIGHT
OPTIONAL
AUX
PLUG IN CONNECT
OR
ON/HI
OFF/LO
LED
IGNITER/SPARKER
SENSING
RED/THERMOPILE
BLACK/THERMOPILE
PILOT GAS TUBING
PILOT
CONTROL BOX
PLUG IN CONNECTOR
CONTROL BOX TO COMMAND CENTER
PLUG IN CONNECTOR
STEPPER MOTOR TO
CONTROL BOX
PLUG IN CONNECTOR
CONTROL BOX TO
SOLENOID
DC POWER/GREEN
VALVE
GROUND
INPUT 300 WATT MAX EACH
GAS IN
GAS OUT
SIGNAtuRe CoMMAND - eleCtRICAl INStAllAtIoN
CA
ut
Io
N
electrical  connections  should  only  be 
performed by a qualified, licensed electrician. 
Main power supply must be turned off before 
connecting fans to the main electrical power 
supply or performing service.
W
ARNING
Before  installing  the  blower,  turn  off  the 
fireplace and allow to cool. only a qualified 
service person should service and repair the 
fireplace. A qualified service person should 
connect and disconnect the fireplace to gas 
supply. Follow all local codes.
Figure 51 -
Signature Command Wiring Diagram
CoMMAND CeNteR WAll INStAllAtIoN
The command center may be mounted on the wall with the use of the SCSWEK Kit (15ft. cable, junc-
tion box, wall cover).
Mount the junction box provided at the desired location on the wall. Do not extend beyond the 15 ft. 
wire cable provided.
Route the wire from junction box to lower control area at bottom of fireplace. Unplug the 1" cable 
from control box and command center. Plug the 15 ft. extension cable into the control box. Remove 
command center from the fireplace and plug the other end of the extension cable into the command 
center. Snap on wall cover provided and screw to junction box.