FLEX VENT INSTALLATION 
Figure 4 — Typical pipe connection
Figure 3 —
Typical vertical fl ex vent installation 
Figure 5 —
Typical horizontal fl ex vent installation
Termination 
cap
Storm collar
Flashing
Rigid pipe
length
Flex to pipe
adapter
(FPA/8)
Fire stop
UL1777 fl ex pipe
DVFA/8 Adapter
Roof support
UL1777
Flex vent
Monessen horizontal 
vent termination
Gear 
clamps
1¾ in. fl exible pipe 
and termination outer 
collar overlap
Securing screws 
(three places 
equidistant, just 
above gear clamp)
Termination to fl ex 
adapter (FTA7/8)
UL1777
Flex vent
Securing 
screws 
(3 places
equidistant 
just above
gear clamp) 
Gear clamp
1¾ in. fl exible pipe 
and adapter outer 
collar overlap
Rigid pipe
length
Gear
clamp
Flex to pipe
adapter 
(FPA/8)
 
 
3.  Do not allow the fl exible vent to bend in radius tighter than 5" (127mm). Refer to Figure 2
  4. 
Horizontal 
runs 
of 
fl exible vent shall be supported at maximum 2 foot intervals; vertical runs, fi ve feet  
 
 
 
intervals. Metal strapping, properly secured, is an acceptable means to support the fl exible vent. 
 
 
5.  Flexible vent spacers are to be installed at intervals prescribed by the fl exible vent manufacture; and in such a   
 
 
way as to maintain concentric inner and outer vent spacing.  
 D. 
Attaching 
fl exible venting to vertical termination assemblies.
 
 
1.  When using Simpson pipe, a MHS fl ex-to-pipe adaptor and/or rigid pipe section(s) is required to connect the    
 
 
fl exible vent assembly to the vertical termination by using three self penetrating screws. 
  2. 
Review 
Figure 4 and corresponding instructions for proper overlap, clamp and screw placement.
 
 
3.  Three each self penetrating screws are drilled opposite one another and below the gear clamp. 
 
 
4.   Use only listed and approved terminations and accessories, installed per the installation instructions and  
 
 
 
Figure 3.
 E. 
Installing 
fl exible venting to horizontal termination assemblies. 
  1. 
Connect 
the 
4" 
fl exible vent to the horizontal termination as in Figure 5.
 
 
2.  Slide termination cap adapter ring over the termination cap’s outside pipe and secure with three screws.
  3. 
Connect 
the 
7" 
fl exible vent to the termination adapter ring as in Figure 5.
  4. 
Review 
Figure 5 for proper overlap and clamp placement
 
 
5.  Three each self penetrating screws are drilled opposite one another and below the gear clamp. 
 
 
6.  Use only listed and approved terminations and  
 
  
 
 
accessories, installed per the termination instructions  
  and 
Figure 5.