Monessen Hearth MJ27PR Manual De Usuario

Descargar
Página de 40
86D0024
IMPORTANT SAFETY INFORMATION
continued from page 3
15. This  is  an  unvented  gas-fired  heater.  It  uses  air 
(oxygen) from the room in which it is installed. Pro-
visions for adequate combustion and ventilation air 
must be provided. See page 8. 
16. Keep room area clear and free from combustible 
materials, gasoline and other flammable vapors and 
liquids.
17. Unvented  gas  heaters  are  a  supplemental  zone 
heater. They  are  not  intended  to  be  the  primary 
heating appliance. 
18. Unvented gas heaters emit moisture into the living 
area. In most homes of average construction, this 
does not pose a problem. In houses of extremely 
tight construction, additional mechanical ventilation 
is recommended. 
19. During  manufacturing,  fabricating  and  shipping, 
various components of this appliance  are treated 
with  certain  oils,  films  or  bonding  agents. These 
chemicals are not harmful but may produce annoying 
smoke and smells as they are burned off during the 
initial operation of the appliance; possibly causing 
headaches or eye or lung irritation. This is a normal 
and temporary occurrence.
    The initial break-in operation should last four hours 
to properly cure logs and rock wool, with the burner 
at the highest setting. Provide maximum ventilation 
by opening windows or doors to allow odors to dis-
sipate. Any odors remaining after this initial break-in 
period will be slight and will disappear with continued 
use.
20. Input ratings are shown in BTU per hour and are for 
elevations up to 2,000 feet. For elevations above 
2,000 feet, input ratings should be reduced 4 percent 
for each 1,000 feet above sea level. Refer to the 
National Fuel Gas Code.
21. The appliance and its appliance main gas valve must 
be disconnected from the gas supply piping system 
during any pressure testing of that system at test 
pressures in excess of 1/2 psig (3.5 kPa).
22. The appliance must be isolated from the gas supply 
piping system by closing its equipment shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 
psig (3.5 kPa).
23.  Do not use this room heater if any part has been 
under  water.  Immediately  call  a  qualified  service 
technician to inspect the room heater and to replace 
any part of the control system and any gas control 
which has been under water.
24. This appliance must not be used with glass doors 
in the closed position. This can lead to pilot outages 
and severe sooting outside the fireplace. 
25. Never burn solid fuels in a fireplace where a unvented 
room heater is installed.
26. Always have a fireplace screen in place when the 
appliance is in operation and, unless other provi-
sions for combustion air are provided, the screen 
must have an opening(s) for induction of combustion 
air. 
Never  connect  unit  to  private  (non-
utility) gas wells.  This gas is commonly 
known as wellhead gas.
W
ARNING
Massachussetts resiDents only:
Please refer to Pages 40 & 41 for
additional information.