After Maintenance/Repair Start-Up
Checklist & Notes
‹
  Inspect and ensure that all components and accessories have been 
installed properly and that they have not been damaged during the 
installation progress.
‹
  Check the condensate water drain(s) to ensure that they are adequate 
for the removal of condensate water, and that they meet the approval 
of the end user.
‹
  Ensure that all installation instructions concerning clearances around 
the unit have been adhered to. Check to ensure that the unit air ¿ lter, 
indoor coil, and outdoor coil are free from any obstructions.
‹
  Ensure that the circuit breaker(s) or fuse(s) and supply circuit wire 
size have been sized correctly. If the unit was supplied with a power 
supply cord, insure that it is stored properly.
‹
  Ensure that the entire installation is in compliance with all applicable 
national and local codes and ordinances having jurisdiction.
‹
  Secure  components  and  accessories,  such  as  a  decorative  front 
cover.
‹
  Start the unit and check for proper operation of all components in 
each mode of operation.
‹
  Instruct the owner or operator of the units operation, and the 
manufacturer's Routine Maintenance.
NOTE:  A log for recording the dates of maintenance and/or service is 
recommended.
‹
  Present the owner or operator of the equipment with the Installation 
& Operation Manual, all accessory installation instructions, and the 
name, address and telephone number of the Authorized Friedrich 
Warranty Service Company in the area for future reference if 
necessary. 
This is a warm weather appliance
Your air conditioner is designed to cool in warm weather when the outside 
temperature is above 60°F (15.6°C) and below 115°F (46.1°C), so it won't 
cool a room if it is already cool outside.
Condensation is normal
Air conditioners actually pump the heat and humidity from your room to the 
outside. Humidity becomes water, and your air conditioner will use most 
of the water to keep the outside coil cool. If there is excessive humidity, 
there may be excess water that will drip outside. This is normal operation.
Frosting
This usually occurs because of insuf¿ cient airÀ ow across the coils, a dirty 
¿ lter, cool damp weather, or all of these. Set the SYSTEM mode to FAN 
ONLY   and the frost will disappear. Setting the thermostat a little warmer 
will probably prevent the frosting from recurring.
Noises
All air conditioners make some noise. Friedrich units are designed to 
operate as quietly as possible. An air conditioner mounted in a wall is quieter 
than one mounted in a window. It is important to ensure that the chassis 
seal gasket (Item 14) is properly installed (refer to installation instructions).
41