INSTALLATION AND OPERATION MANUAL
MF3700, MF3800 Models
Page 3
800-345-6007
CumberlandStoveWorks.com
VENTING
Consult  vent  manufacturer’s  specifications  and 
recommendations for all venting installations. 
The following installation guidelines must be followed to 
ensure conformity with both the safety listing of this stove 
and to local building codes.
note:  where passage through a wall, or partition of 
combustible construction is desired, the installation 
shall conform to Can/CSa -8365. 
TYPE OF VENT
Pellet venting pipe (also known as L vent) is constructed
of two layers with air space between the layers. This air 
space acts as an insulator and reduces outside surface 
temperature of pipe to allow a clearance to combustibles. 
A UL listed 3” or 4” type L pellet vent exhaust system must
be used for installation and attached to the pipe connector 
provided on the back of the stove. Use a 3” to 4” adapter
for 4” pipe. A cap must be used at the termination of type
L vent chimneys. For elevations above 2,500 feet above 
sea level, a 4” L is required.
PELLET VENT INSTALLATION
Termination 
MUST exhaust above air inlet elevation.
It  is  recommended  to  install  at  least  3’  of  vertical  pellet 
vent pipe.  This will create some natural draft to prevent the 
possibility of smoke or odor during appliance shutdown and 
to keep exhaust from causing a nuisance or hazard from
exposing people or shrubs to high temperatures.
The  installation  must  include  a  clean  out  tee  to  enable 
collection of fly ash and to permit periodic cleaning of the
exhaust system.
Total length of horizontal vent must not exceed 10 feet.
The maximum recommended vertical venting height is 18
feet. All joints for pellet vent are required to be fastened 
with at least three screws and all pellet vent connections 
must  be  sealed  according  to  the  vent  manufacturer’s 
recommendations. 
The area where the vent pipe goes through to the exterior
of the home must be sealed with silicone or other means 
to maintain the vapor barrier between the exterior and the
interior of the home. 
 WARNING
DO  NOT  CONNECT  THIS  UNIT  TO  A  CHIMNEY  FLUE 
SERVING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST 
VENTING SYSTEM OF THIS UNIT.
DO  NOT  CONNECT  DIRECTLY  TO  A  MASONRY 
CHIMNEY.
DO NOT TERMINATE VENT IN ANY ENCLOSED OR SEMI-
ENCLOSED  AREA,  SUCH  AS;  CARPORTS,  GARAGE, 
ATTIC, CRAWL SPACE, UNDER A SUN DECk OR PORCH, 
NARROW  WALkWAY  OR  CLOSED  AREA,  OR  ANY 
LOCATION THAT CAN BUILD UP A CONCENTRATION 
OF  FUMES  SUCH  AS  A  STAIRWELL,  COVERED 
BREEZEWAY ETC.
 CAUTION
VENT SURFACES CAN GET HOT ENOUGH TO CAUSE 
BURNS IF  TOUCHED. NONCOMBUSTIBLE SHIELDING 
OR GUARDS MAY BE REqUIRED.
PELLET VENT MUST MAINTAIN MINIMUM CLEARANCES 
SPECIFIED BY VENT MANUFACTURER FOR CLEARANCE 
TO ANY COMBUSTIBLES.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE 
VENT MANUFACTURER.
ALL VENTING, WHETHER VERTICAL OR HORIZONTAL, 
JOINTS  SHOULD  BE  MADE  GAS-TIGHT  WITH 
RECOMMENDED SEALANTS.