Cooper Lighting P4R Prospecto

Descargar
Página de 2
Exploded view and part call-out
Canopy
Set screw
1/4-20 x 4 1/2"
 Hex cap bolts
(4x)
(by others)
J-box
#8-32 x3/8"
(2x)
(4x)
1/4" Fastener
Cover plate
Wiring the fixture
1.  Remove all 1/4-20 x4 1/2" hex bolts from bottom of pendant. 
2.  Remove both #8-32 x 3/8" set screws and allow canopy to 
     slide down pendant.
3.  Run wires from J-box into pendant, ensure there is enough 
     wire to reach cover plate.
4.  Using appropriate fasteners, secure fixture to ceiling.  Use 
     additional bracing around J-box to support fixture.
5.  Replace canopy and secure using both set screws.   
Yoke arm 
indicator
Aiming the fixture
Fixture head 
indicator
1.  To aim fixtures, loosen both #10-32 end screws on one 
     fixture.  When both indicators are lined up, the slope of the 
     lens face is 40-degrees.  Each subsequent notch is an 
     additional +/- 10-degrees.
2.  When fixture head is rotated to the desired angle, retighten 
     end screws to secure the position.  
3.  Repeat for remaining fixture heads.
Set screw
Mounting pendant to J-box
(4x)
(by others)
1/4" fasteners
(by others)
J-box
(2x)
(4x)
Hex cap bolts
1/4-20 x4 1/2"
#8-32 x3/8"
Canopy
Cover plate
Use additional bracing 
around J-box to support 
fixture.
4.
Cover plate
  Push connections into pendant and secure cover plate.
     properly matched.
1/4-20 x4 1/2"
Fixture wire 
Hex cap bolts
(4x)
1.  With pendant secure, slide fixture assembly onto pendant 
     and secure with four 1/4-20 x4 1/2" hex bolts.
2.  Remove cover plate and insert wires from fixture heads into 
     pendant and pull through opening.
3.  Attach appropriate wires and ensure all connections are 
Attention:
Quad fixture assemblies require additional bracing/structure
around J-box to support fixture.
2
that all sources of power are turned off.  All 
Sheet 1 of 2
performed by a certified electrician.  
ADY071466   REV B(ECN80481)
 
Warning
:  Before starting any work ensure 
work must meet local/national codes and be 
Do not
mount fixtures vertically. 
Installation Instructions
Vault
C-Scroll
Roundel
These installation instructions are valid with the above Ametrix styles.
1
3
Small, INDOOR
P4R 
(Pendant, 4-way, Remote ballast)
Visor and Non-Visor