Important Notes 
CLS-C6RF & CLS-C6MRF Specifications (Continued) 
SPECIFICATION 
DETAILS 
Environmental Temperature 
32° to 104°F (0° to 40°C) 
Humidity 
10% to 90% RH  
(non-condensing) 
Overall Dimensions: 
 Height 
 Width 
 Depth 
 
4.48 in  (11.38 cm) 
8.89 in  (22.58 cm) 
2.47 in  (6.25 cm) for CLS-C6 
2.60 in  (6.61 cm) for CLS-C6M 
Weight  
22.8 oz (646.37 g)  
Read before installation. 
•  Codes: Install in accordance with all local and 
national electrical codes. 
•  Wiring: Use copper wire only. For supply 
connections, use wires rated for at least 75°C. 
•  Lighting Load Types: incandescent, magnetic 
low voltage, neon/cold cathode, dimmable  
2-wire fluorescent, and non-dim lighting  
(also: electronic low voltage, 3-wire and 4-wire 
fluorescent, and 277V via expansion modules; sold 
separately).  
1.  Additional load types can be controlled and load ratings can be increased via 
optional CLS-EXP expansion modules. Refer to the Crestron website 
 for details. 
•  Temperature: The iLux units are designed for use 
where temperatures are between 32° to 104°F  
(0° to 40°C). 
2.  The latest software versions can be obtained from the Crestron website. Refer to 
the NOTE following these footnotes. 
3.  Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest 
Crestron Product Catalog for a complete list of 2-Series control systems. 
•  Wallboxes: The iLux units mount in standard  
4-gang wallboxes; 3.5 inches deep, minimum.  
NOTE:  Crestron software and any files on the website are 
for Authorized Crestron dealers and Crestron Authorized 
Independent Programmers (CAIP) only. New users may be 
required to register to obtain access to certain areas of the 
site (including the FTP site) 
•  Make certain that power is turned off, and 
ensure that there is at least 4.5 inches of open 
space above and below the electrical box location 
to permit heat dissipation. 
Physical Description 
Installation 
The following illustration shows the overall dimensions for 
the CLS-C6RF and CLS-C6MRF. 
WARNING:  Turn off power at the distribution panel 
circuit breaker. Installing with power on can result in 
serious personal injury and damage to the device. 
CLS-C6MRF Overall Dimensions 
 
CAUTION: To reduce the risk of overheating and possible 
damage to other equipment, do not install to control a 
receptacle or a motor-operated appliance. 
NOTE:  The CLS-C6RF units require a neutral wire for 
operation. If no neutral is present, contact a licensed 
electrician for installation. 
The following tools/hardware are required for installation. 
•  A 4-gang electrical box (not supplied), 3.5 inches 
deep, minimum.  
•  Phillips torque screwdriver (not supplied) 
Industry Compliance 
•  Four 7/8-inch pan head Phillips screws (supplied) 
This product is Listed to applicable UL Standards and 
requirements by Underwriters Laboratories Inc. 
If the planned configuration includes connection to shade 
controllers, keypads, and/or a Crestron 2-Series control 
system, the following items are also required. Refer to the 
latest version of the Crestron CLS-C6RF iLux Integrated 
Lighting System w/infiNET Operations Guide (Doc. 6418) 
for detailed configuration options. 
     
(E103692)
 
NOTE:  This device complies with part 15 of the FCC 
rules. Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and (2) 
this device must accept any interference received, including 
interference that may cause undesired operation. 
•  Cresnet network cable(s) (not supplied) 
•  Terminal block connector(s) (two supplied) 
2  
 iLux
 Integrated Lighting Systems w/infiNET
:  CLS-C6RF & CLS-C6MRF 
Installation Guide – DOC. 6416A