Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically between 2,000 
and 3,000 hours depending on the Lamp Power setting), or sooner if a noticeable 
degradation in brightness occurs. 
Keep track of the number of hours the lamp has been in use and be aware of any changes 
to brightness. These indicators will help you effectively maintain operation of the projector. 
To find out how long the currently-installed lamp has been in service, select Display Info. 
from the Display Device - Configure menu (available by selecting Service -> Display 
Device -> Configure -> Display Info.
, in sequence). 
For lamp or filter replacement, please contact your nearest Runco authorized 
service center or Runco dealer. Do not attempt to replace the lamp yourself!
1.
Turn off the projector and unplug the power cord. Allow the projector to cool 
down for approximately 45 minutes prior to removing the lamp assembly for 
replacement. 
2.
Loosen the two rear Lamp Cover screws and 
remove the cover.
3.
Remove the two lamp assembly mounting screws.
4.
Grasp the lamp assembly handle and pull gently, removing the lamp module from the 
projector housing.
5.
Install the new lamp module. 
6.
Replace the lamp cover and re-tighten all screws.
7.
Turn on the Dimension Digital Controller and projector. 
8.
Reset the Lamp Hour counter. To do this, select Lamp Hours Reset from the Display 
Device - Configure m
enu. A confirmation dialog box appears. Select “Yes,” then press 
ENTER to continue with the reset or “No” to cancel the operation. 
5. Maintenance and Troubleshooting
REMOVE THESE SCREWS