Runco Home Theater Projection System Manual De Usuario

Descargar
Página de 152
LightStyle™ LS-12HBd Installation/Operation Manual
73 
L
IMINAR
Y
Use the Calibration menu to perform advanced picture quality adjustments. This menu 
should be used by ISF-certified technicians only. 
To recall the ISF Night or ISF Day settings, select “ISF Night” or “ISF Day” from the 
Memory Presets menu (see page 70) or use the corresponding remote control buttons. 
Display Color - Common Settings: Use the Display Color - Common Settings menu to 
adjust the color balance at the Dimension Digital Controller output. These settings are 
saved independently for each input and display mode.
• Gain: Use the Gain controls to correct color imbalances in the bright areas of the 
image. A good way to do this is to use a test pattern consisting mostly of solid white 
areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red (Pr), 
green (Y) or blue (Pr), decrease the Gain for that color.
• Offset: Use the Offset controls to correct color imbalances in the dark areas of the 
image. A good way to do this is to use a test pattern consisting mostly of dark gray 
areas, such as a 30 IRE “window” pattern. If the gray areas contain traces of red (Pr), 
green (Y) or blue (Pr), decrease the Offset for that color.
de-gamma curve. Used correctly, the Gamma control can improve contrast while 
maintaining good details for blacks and whites. If excess ambient light washes out the 
image and it becomes difficult or impossible to see details in dark areas, lower the 
gamma setting to compensate. This improves contrast while maintaining good details 
for blacks. Conversely, if the image is washed out and unnatural, with excessive detail 
in black areas, increase the setting. 
• ModeWith the LS-12HBd, two Gamma adjustment modes are available: Simple o
Advanced. The two modes are mutually exclusive; when you select the Simple 
mode, the Advanced selection in the Gamma menu is grayed out. Likewise, when 
you select Advanced, the Simple selection is grayed out.
• Simple: Use the Simple Gamma control to perform gamma correction at the display 
according to a simple power law gamma function. The value chosen here 
corresponds to the power variable in this equation:
Output = Input
Power
The Dimension Digital Controller applies this gamma curve to all three primary color 
channels (red, green and blue). 
• Advanced: To select a custom gamma curve, select Mode from the Gamma men
and set it to Advanced. Then, select Advanced from the Gamma menu to select one 
of up to 20 pre-programmed gamma tables. Custom gamma tables provide the 
ability to perform complex, non-linear gamma correction on each primary color 
channel independently of the others.
ISF Settings
Display Color
You must enter a passcode to access the Calibration menu. 
Note