Brother BAS-311E Manual De Propietario

Descargar
Página de 150
105
BAS-311E.311EL.326E.326EL
Chapter 7
#1.2
No 
switches 
on the 
panel are 
not 
activated.
#2 
If the R/W 
switch is 
pressed, 
the 
indicator 
lamp is not 
lit and an 
error code 
appears.
Probable cause
11. With error code [E.c4], 
overcurrent has occurred in Y-
pulse motor.
12.  With error code [E.c5], the box 
cooling fan (at the right when 
viewed from the front) is 
defective.
13. With error code [E.E0], the [MN] 
PROM on the control circuit 
board is defective.
14. With error code [E.F0], the relay 
on the power PCB is not 
working.
15. With error code [E.F1], the cord 
is not securely inserted.
16. With error code [E.F2], 
overcurrent has occurred in 
power PCB.
1.
Panel PCB is not correctly 
attached.
2.  Panel PCB is defective.
3. Programmer 
detective.
1.  With error code [E.40], the cord 
or the floppy disk drive (FDD) is 
defective.
Check/repair/adjust
• Check that connector P6 (YPM) on the control 
circuit board is securely inserted and the Y-pulse 
motor is correctly wired.
• Refer to #1.1-2
• Refer to #1.1-8 [E.CI]
• Check that connector P25 (FAN-L) on the control 
circuit board is securely inserted.
• Check that the PROM of the control circuit board 
is securely inserted and its leads are not bend.
• Check that MN and MT of the PROM are matching 
those on the main PCB.
• If the PROM has no problem, check the 
connection between pin 3 in connector P18 
(PANEL) on the control circuit board and pin 5 in 
connector P5 (DRV) on the panel PCB.
• Check that the PER code is securely inserted (refer 
to #1.1-15).  If the error appears, replace the 
power PCB with a new one.
• Check that connector P2 (PER) of the power PCB 
and connector P20 (PER) on the main PCB are 
securely inserted.  Check there is no damage in 
wiring.
• Find a cause of noise.  (Refer to #1.1-2.)
• Replace the power PCB .  (Refer to #1.1-14.)
• Check whether the panel setting plate makes 
contact with a switch.
• Refer to #1-7
• Pull out the programmer.  If a switch is activated, 
the programmer is defective.
• Check the connections and pins between 
connector P1 on the panel PCB and the FDD, and 
between connectors CH1 and CH2 on the panel 
PCB and the FDD.
• Replace the floppy disk drive.
Parts to be replaced
Y pulse motor 
control circuit 
board.
Fan motor 
assembly
PRON
Panel code
Power PCB
PER code.
Power PCB
Panel circuit 
board
Programmer
FDD Harness
Floppy disk drive
Error status
#1 The 
power 
lamp does 
not light 
when the 
power is 
turned on.