3com 3CB9LF36R Manual De Usuario

Descargar
Página de 60
48
C
HAPTER
 4: S
OFTWARE
 I
NSTALLATION
Downgrading 
Switching Modules 
to Software 
Release 2.1.0
Follow this procedure to downgrade the switching modules in your 
chassis that are running software Release 3.0 to software Release 2.1.0:
CAUTION: The 36-port 10/100BASE-TX Desktop Switching Modules 
(Model Numbers 3CB9LF36RL and 3CB9LF36TL) cannot be downgraded 
to software releases earlier than Release 3.0.0.
Download the operational code for your previous software Release 2.1.0 
to all the switching modules that are installed in your chassis.
Download the boot code for your previous software Release 2.1.0 to all 
the switching modules that are installed in your chassis.
Download the diagnostic code for your previous software Release 2.1.0 
to all the switching modules that are installed in your chassis.
Do not reset the modules after you complete the downgrade. You must 
now downgrade the software code on the switch fabric modules that are 
installed in your chassis. See the procedure in “Downgrading Switch 
Fabric Modules to Software Release 2.1.0” in the 
CoreBuilder 9000 
Release Notes for Gigabit Ethernet (GEN) Switch Fabric Modules and GEN 
Interface Modules.