•  Do not use vaseline, oils, other hydrocarbon lubricants or 
spray silicone anywhere.  A silicon lubricant may be used 
on black o-rings but is not necessary.  Avoid any type of 
lubricants, including silicone, on red or clear lip seals.
•  Do not use pipe dope or other sealants on threads.  Only teflon 
tape may be used on threads.  Teflon tape is not necessary 
on the nut connection or caps because of o-ring seals.
•  The pipe size for the drain line should be a minimum of 3/4”.   
Backwash flow rates in excess of 7 gpm or length in excess 
of 20’ require 1” drain line.
1.   Place the conditioner where you want to install it, making 
sure it is on a clean, level and firm base.
2.   Do all necessary plumbing (inlet to inlet, outlet to outlet and 
drain line to drain).  The control valve, fittings and/or bypass 
are designed to accommodate minor plumbing misalignments 
but are not designed to support the weight of a system or 
the plumbing.
3.  When assembling the installation fitting package (inlet and 
outlet), connect the fitting to the plumbing system first and 
then attach the nut, split ring and o-ring.  Heat from soldering 
or solvent cements may damage the nut, split ring or o-ring.  
Solder joints should be cool and solvent cements should 
be set before installing the nut, split ring and o-ring.  Avoid 
getting primer and solvent cement on any part of the o-rings, 
split rings, bypass valve or control valve.
4.  A jumper ground wire should be installed between the 
inlet and outlet pipe whenever the metallic continuity of 
a water distribution piping system is interrupted.  Install 
jumper ground wire on metal pipes.
5.   The drain connection may be made using either 5/8” polytube 
(See figure 6a, page 6) or a 3/4” female adapter.  If soldering, 
joints near the drain must be done prior to connecting the 
drain line flow control fitting.  Leave at least 6” between the 
drain line control fitting and solder  joints when soldering pipes 
that are connected on the drain line control fitting.  Failure 
to do this could cause interior damage to the drain line flow 
control fitting.
6.   The brine refill flow control assembly is installed in an easy 
to access refill elbow located on top of the control valve.  
The refill flow control assembly is attached to the control 
valve with a locking clip.  The locking clip allows the elbow 
to rotate 270 degrees so the outlet can be orientated towards 
the saltkeeper.
7.   Connect the brine line found in the brine tank to the brine 
connection on the control valve.  The control valve has a 
standard refill elbow which a 3/8” flexible tube can be con-
nected, see figure 6a, page 6.  (An optional elbow can be 
ordered which accommodates a 1/2” flexible tube for a high 
regenerant draw rate situation).  Both elbows use the same 
refill flow control and retainer.  Do not connect the other end 
of the brine line to the safety brine valve in the brine tank at 
this time. Make sure the floor is clean beneath the salt tank 
and that it is level and smooth.
8.  A 1/2” (inside diameter) gravity drain line should be connected 
to the overflow elbow on the side of the brine tank and run to 
a drain below the level of the elbow.  This overflow drainage 
system provides protection from water damage in the event 
of a brine shut-off malfunction.  Tubing is not provided to 
do this.
 
In all cases where an overflow could result in water dam-
age for various reasons, this overflow protection must be 
used.  Do not connect the tubing to the drain line on the 
control valve discharge line and do not run this line above 
the overflow elbow height at any point.  Provide air gap.
 
insTallaTiOn insTruCTiOns
(All electrical & plumbing should be done in accordance to all local codes)
Figure 6a
Drain 
Connection
Brine Line
Connection
Figure 6b