Crestron electronic C2N-VEQ4 Manual De Usuario

Descargar
Página de 40
Crestron C2N-VEQ4 
Cresnet 4-Channel Digital Volume Control
 
Operations Guide - DOC. 6135A 
Cresnet 4-Channel Digital Volume Control: C2N-VEQ4  
  9 
possible for the control system to recognize a network device via its serial number, 
which is stored in the device’s memory. This method does not require that any 
devices be disconnected from the network; Net IDs may be set with the entire Cresnet 
system intact. This method requires the use of the Crestron Viewport version 3.35 or 
later. 
Use the appropriate method to set the C2N-VEQ4 Net ID. 
Method A (Cresnet address-settable ID) 
1. 
Ensure that the C2N-VEQ4 is the only device connected to the control 
system.  
2. 
Open the Crestron Viewport.  
3. 
From the Viewport menu, select Functions | Set Network ID. The 
software checks the baud rate and then opens the "Set Network ID" 
window.  
4. 
In the "Set Network ID" window, select the C2N-VEQ4 from the 
Current Network Devices text window.  
5. 
Select the new Net ID for the C2N-VEQ4 from the Choose the new 
network ID for the selected device (Hex):
 text box.  
6. Click 
Set ID to initiate the change. This will display the "ID command 
has been sent" window.  
7. 
In the "Command Complete" window, click OK.  
8. In 
the 
Current Network Devices text window, verify the new Net ID 
code.  
9. 
In the "Set Network ID" window, click Close.  
NOTE:  The new Net ID code may also be verified by selecting Diagnostic | Report 
Network Devices
 in the Viewport (alternately, select F4).  
10. 
Repeat this procedure for each C2N-VEQ4 to be added to the system. 
Method B (Touch Settable IDs) 
Before using this method, you should have a list of all current network devices and 
their Net IDs, to avoid assigning duplicate IDs.  
Set Net ID by TSID 
These procedures are for TSID-enabled network devices during the initial 
configuration of a Cresnet system or when such devices are being added/replaced. 
1. 
Ensure that all C2N-VEQ4s are connected to the control system.  
2. 
Open the Crestron Viewport version 3.35 or later.  
3. 
From the Viewport menu, select Functions | Assign Cresnet ID by 
Serial Number
. The “Set Net ID by TSID” window appears. The 
window is first displayed with the data fields empty.