Lucent Technologies Release 7 Manual De Usuario
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-764
ETH-PT (Control LAN Ethernet)
9
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 1: Ethernet Local Looparound Test (#1278) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to repair procedures for Test #1278.
Table 9-295.
ETH-PT Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp s
1 (a)
0
Ethernet Local
Looparound
Test (#1278)
Looparound
Test (#1278)
MINOR
ON
test port UUCSSpp l r 3
513 (b)
0
Link Integrity Inquiry
(#1282)
(#1282)
MINOR
OFF
test port UUCSSpp r 2
769 (c)
0
Invalid Frame Error
WNG
OFF
1281 (d)
0
Far-end Disconnect
1537, 1538
(e)
(e)
See
note
note
Session Status Test
(#1286)
(#1286)
MINOR
OFF
1793-1920
(f)
(f)
See
note
note
Socket failure
2305-2560
(g)
(g)
See
note
note
Session Down error
Session #s 1-256
Session #s 1-256
2561-2816
(g)
(g)
See
note
note
Session Down error
Session #s 257-512
Session #s 257-512
3329 (h)
See
note
note
TCP/IP Ping Test
(#1281)
(#1281)
WNG
OFF
Continued on next page