DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-335
test eda-external-device-alrm 
8
The following display shows a typical result when test duplication-interface is 
entered and A is the active carrier of a duplicated SPE system.
test eda-external-device-alrm
test eda-external-device-alrm all | physical location [repeat number | clear][ 
schedule]
This test will perform hardware diagnostic tests on an individual 
external-device-alarm port or on all external-device-alarm ports.
The test eda-external-device-alrm command performs a hardware diagnostic 
test on all administered external device alarms if all is entered. If an administered 
external device alarm port is entered, the test external-device-alarm command 
performs a hardware diagnostic test on that port. The test PASSES if the external 
device is not reporting an external device alarm and FAILS if the external device 
is reporting an external device alarm. If the technician specifies the port it must 
be administered as an external device alarm port on a maintenance board or on 
an analog line port carrier board.
Defaults
The default for this command is a repeat of 1.
Test No.
The number of the test being executed.
Result
An indicator as to whether the test failed, passed or was aborted.
Error Code
A numerical description of why the test failed or was aborted.
 
 test duplication-interface
 
                               TEST RESULTS
                                  
 Port  Maintenance Name  Alt. Name  Test No.    Result   Error Code
 
 01B       DUPINT                      979      PASS
 01A       DUP-CHL                     980      PASS
 01A       DUP-CHL                     874      PASS
 01A       DUP-CHL                     875      PASS
 01A       DUP-CHL                     876      PASS
 
 Command Successfully Completed