Lucent Technologies Release 7 Manual De Usuario

Descargar
Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-338
test environment 
8
test environment
test environment UU [short | long] [repeat # | clear] [schedule]
The test environment command performs hardware diagnostic tests of the 
environment monitoring and control, and emergency transfer functions of a 
specified cabinet. This command tests both PPN and EPN cabinets. Circuit 
packs involved are the SYSAM (PPN) EPN Maintenance, and tone/clock (for the 
ring generator test.
!
CAUTION:
The long test recycles power on all port circuit pack carriers and is 
destructive. It does not recycle power on active or standby PPN or EPN 
control carriers or switch node carriers. When a port carrier is recycled, all 
service and links to ports on the carrier are dropped. If a carrier containing 
an active EI or tone-clock is recycled, all service to that cabinet will be 
disrupted.
There are nine Maintenance Objects involved in this test:
Note that although the CUST-ALARM maintenance object is part of the 
environment functionality, it is not actually tested using the ‘test maintenance’ 
command. See ‘test customer-alarm’ for details on testing this particular MO.
Output
The following display shows a typical result when test environment 1 is entered 
in order to test the PPN cabinet.
Error Code
A system-generated number that tells why the release failed or aborted. 
A detailed list of the codes according to “Test No.” is provided for each 
MO.
EMG-XFER
POWER
RING-GEN
AC-POWER
DC-POWER
CUST-ALARM
CARR-POW
CABINET
EXT-DEV