Maintenance Object Repair Procedures
9-161
ATM-BCH (ATM B-Channel Trunk)
9
2208
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2209-
2210
2210
ABORT
Could not allocate needed resources
1. Follow recommendations for ABORT code 2100.
2211
ABORT
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2212
ABORT
Call terminated by unexpected disconnect
1. Wait 1 minute and then try again.
2213
ABORT
Call timed out
1. Wait 1 minute, and try again.
2214
ABORT
Call terminated by unexpected disconnect
1. Wait 1 minute and then try again.
2215-
2219
2219
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2220
ABORT
Call terminated prematurely
1. Wait 1 minute, and try again.
2221-
2226
2226
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2227
ABORT
Could not allocate needed resources
1. Retry the command at 1-minute intervals a maximum of 5 times.
2042
FAIL
Test data corrupt
PASS
Test pattern intact. If the synchronous test call was performed (long test
sequence), the communications path is operating properly.
sequence), the communications path is operating properly.
Table 9-68.
TEST #258 ISDN Test Call — Continued
Error
Code
Code
Test
Result
Description/ Recommendation
Continued on next page