Maintenance Object Repair Procedures 
9-164
ATM-DCH (ATM D-Channel Port) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
The command to test the ATM-DCH maintenance object is test port UUCSSpp
where pp is for ports 9-32.
Signaling Link Board Check (#643)
This nondestructive test checks the health of the ATM TN230X Trunk circuit pack 
hardware. The test runs on a periodic or scheduled basis, during initialization 
testing, and upon demand. 
NOTE:
The board-level maintenance is handled independently of the ATM-CES 
signaling link maintenance, raising the possibility of inconsistent states. 
Table 9-70.
System Technician-Demanded Tests: ATM-DCHL
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Signaling Link Board Check (#643)
X
X
ND
Continued on next page
Table 9-71.
TEST #643 Signaling Link Board Check 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal System Error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
8
FAIL
The TN230X circuit pack is not in-service.
1. Check the Error Log for ATM-TRK errors and resolve any using 
(Circuit Emulation Service Circuit Pack)’’
.
PASS
The ATM TN230X circuit pack is in-service.