Lucent Technologies Release 7 Manual De Usuario

Descargar
Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-233
ATM PNC-DUP (ATM PNC Duplication) 
9
Table 9-98.
Error Code descriptions and Aux Data correlations
Error 
Code
Description
Aux Data
1
1.
The Aux Data indicates which PNC became active after the PNC interchange: “0” denotes PNC-A; 
“1” denotes PNC-B.
00000
Error in generating error code
None
1cxpp
Spontaneous Interchange in response to a constraint for A-PNC
Active PNC
2cxpp
Spontaneous Interchange in response to a constraint for B-PNC
Active PNC
51000
Spontaneous Interchange at expiration of SOH validation timer
Active PNC
52000
Spontaneous Interchange upon PNC UNLOCK
Active PNC
53000
Spontaneous Interchange at completion of Global Refresh
Active PNC
60801
PNC Demand Interchange
Active PNC
60800
PNC Demand Interchange with override
Active PNC
Continued on next page
Table 9-99.
Error Log Encode Field Decoding
Field
Variable Name
Values
Description
c
Alarm Type
0
1
Alarm retired
MAJOR or MINOR alarm on any PNC component
x
Fault class; see 
description for 
contributing MOs
0
EAL (Expansion Archangel Link - EXP-PN) carries 
CCMS messages
1
PACL (ATM-EI) carries ATM signaling commands 
from Call Processing to the remote ATM-EI circuit 
packs.
2
PNC hardware (providing connectivity of PPN or EPN 
to EPN or ATM-EI)
pp
Port Network number
0-44
0-2 for constraint class (this is an internal number; 
add 1 for external port number)
Continued on next page