Test Telephones and Other Equipment 
Page 6-4
Test Music-on-Hold 
6
Test Music-on-Hold
Verify music is provided to a held party during any hold interval.
Test Emergency Transfer
Put system in emergency transfer mode and make call using emergency transfer 
telephone. There may be up to 4 Emergency Transfer switches depending on the 
system configuration. The switch is located on the Processor circuit pack(s) in 
the Processor Port Network (PPN) Control Carrier.
Test Remote Access Interface
Test the communication link between the system and the remote interface 
(formerly INADS) and verify the alarm notification process. Make a remote test 
from the remote interface to the DEFINITY System and a local test from the 
DEFINITY System to the remote interface.
In some countries, this remote access interface is not allowed. Contact your 
Lucent Technologies representative.
Remote Test
1. Call outside personnel who will be accessing the system remotely to 
perform administration, maintenance, and testing.
2. Ask remote personnel to call system and login and display System 
Parameters Maintenance screen. The login must be successful.
NOTE:
Product Identification on the System Parameters screen must match 
the Product Identification administered by the local technician.
3. Have the remote personnel enter the test inads-link command, terminate 
the login, and disconnect.
4. Have the remote personnel check the appropriate trouble ticket. The 
trouble ticket should show “INADS,n,MINOR” in the description field to 
indicate a minor off-board alarm was reported to the remote personnel. 
There may be more text in the description field if other resolved alarms 
were reported.
5. Have the remote personnel make second call and login to the system and 
check the error log to verify no problems. See 
DEFINITY Enterprise 
Communications Server Release 6 Maintenance for R6r
, for error log and 
error code information.