Table 7: Air Flow Specifications and Fan Tray Support
Air Volume
Air Filter Available
Airflow Exhaust
Airflow Intake
Fan Tray Model Number
850 CFM
No
Left side
Right side
C6807-XL-FAN
Figure 6: Air Flow Direction
Module air exhaust
3
Module air inlet
1
Power supply air exhaust
4
Power supply air inlet
2
Humidity
High-humidity conditions may cause moisture to enter the system, and cause corrosion of internal components
and degradation of properties such as electrical resistance, thermal conductivity, physical strength, and size.
Extreme moisture buildup inside the system may result in electrical short circuit, which may cause serious
damage to the system. Each system is rated to operate at 5 to 90 percent relative humidity, with a humidity
gradation of 10 percent per hour. In storage, a system can withstand 5 to 95 percent relative humidity. Buildings
in which climate is controlled by air-conditioning in the warmer months and by heat during the colder months
usually maintain an acceptable level of humidity for system equipment. However, if a system is located in an
unusually humid location, a dehumidifier should be used to maintain the humidity within an acceptable range.
Cisco Catalyst 6807-XL Switch Hardware Installation Guide    
   OL-30656-01
17
Preparing for Installation
Humidity