WARNING: To reduce the risk of electric shock, 
disconnect from power supply before servicing.
To clean blower assembly: Remove access panel, unplug blower 
from housing, remove blower mounting nuts, and carefully remove 
blower from housing. Use appropriate vacuum attachment or a soft 
cloth and mild soap or detergent to clean blower discharge area and 
wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure 
blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
USE AND CARE
Follow wiring instructions packed with range hood, and adhere to 
all local and state codes, and the National Electrical Code.
ATTACH POWER CORD TO 
HOOD
Some hoods require the use of a separate power cord and strain 
relief bushing (included), for proper wiring of in-line blowers. Please 