Dimension One Spas Bay Collection Manual De Usuario

Descargar
Página de 72
2004 Bay Collection 
Owner’s Manual 
 
Infrared Sensor – All Models 
 
Remotely Control 
Spa Functions 
The infrared sensor, located on the 
Top Side Control,  allows you to 
remotely control the following spa 
features, or functions, using the 
optional D1 Remote Control
 
• 
Jets  
• 
Water Feature/Fountain 
• 
Interior Spa Lights 
• 
iWatch Exterior Perimeter 
Lighting 
UltraPure™ Water Management System – All Models 
This spa is equipped with a highly advanced hot tub water treatment method, the UltraPure™ Water 
Management System. The UltraPure™ Water Management System is an integrated water management system 
with ozone injection, dual contact chambers, and 24-hour filtration. 
 
 
Energy conversation is designed into the UltraPure™ Water Management System. The 
circulation pump has a built-in heat recovery system that diverts circulation pump heat directly 
to the spa water. This feature reduces demand on the spa heater, and saves energy. 
 
To prevent the hot tub from overheating, the circulation pump turns off when the water 
temperature rises 2° F (≅1.1° C) above the set temperature. When the water temperature 
cools down to the set temperature, the circulation pump will turn back on. 
 
 
 
 
The circulation pump will run for short periods when the water temperature is 2° F (≅1.1° C) 
above set temperature to verify temperature. 
Vision – All Models 
Vision, an alternative purification system, can be used in conjunction with your UltraPure™ Water 
Management System. The advantage of Vision over conventional halogens (bromine and chlorine) is that it will, 
as a result of lower chemical use, provide softer-feeling water. Additionally, low chemical levels can mean 
fewer dissolved solids, which results in less water chemistry maintenance. Please refer to the Vision 
instructions for proper installation. Also read the Water Care Guide for more information. 
Smart Heat – All Models 
On all Dimension One Spas, when the water temperature is at least 1° F (≅0.55° C) below the set 
temperature the heater will turn on and remain on until the water temperature rises to 1° F (≅0.55° C) above 
the set temperature. Smart Heat recognizes the difference between the set temperature and the actual water 
temperature, then determines the rate of heating required to best maintain the set temperature. 
Load Sharing – All Models 
Load Sharing recognizes the number of jet pumps in use and compares it with the available power. 
Computerized load sharing adjusts the heater to maximize the heater output based on heat requirements and 
spa operation, then optimizes heat recovery using the amperage that you have available.  
22