MGS0650B 
 
 
 
L-6, 4 stroke-cycle water-cooled, turbocharged and aftercooled 
ENGINE SPECIFICATIONS & TECHNICAL DATA 
 
 
Bore 
mm 
170 
Stroke 
mm 
220 
Displacement 
30 
Piston speed 
m/sec. 
11 
Compression ratio 
 
14 
Lubricating oil capacity 
100 
Coolant capacity without radiator 
55 
Coolant pump external resistance 
m water 
5.0 
Coolant pump flow rate 
L/min 
670 
Cooling fan airflow rate 
m
3
/min 
720 
Cooling fan air flow restriction 
kPa 
0.1 
Ambient air temperature 
℃ 
40 
Allowable exhaust back pressure 
kPa 
6.0 
Exhaust flange size (internal diameter) 
mm 
200 
 
 
ENGINE OPERATING DATA 
 
 
 
Gross Engine Power* 
kWm 
668 
605 
Brake mean effective pressure 
MPa 
1.8 
1.6 
Regenerative absorption 
kW 
64 
64 
Noise Level at 1 m 
dB(A) 
106 
104 
(excluding: intake, exhaust & fan) 
 
 
 
Fuel consumption load 
100%* 
L/hr. 
162 
147 
Fuel consumption load 
75%* 
L/hr. 
121 
111 
Combustion air inlet flow rate 
m
3
/min 
56 
51 
Exhaust gas flow rate 
m
3
/min 
147 
133 
Exhaust gas temperature 
℃ 
510 
500 
Heat rejection to coolant 
kW 
404 
366 
Heat rejection to exhaust 
kW 
476 
438 
Heat rejection to atmosphere from engine 
kW 
48 
44 
Heat rejection to atmosphere from generator 
kW 
41 
36 
* WITH FAN basis. 
 
Deration for engine 
Altitude: 2.5% per 300m (1000ft) above 1,500m 
Temperature: 2% per 5℃  (9°F) above 40℃ 
 
 
ENGINE STANDARD EQUIPMENT 
Aftercooler 
Turbocharger filter 
Structure steel base 
Crankcase breather   
Charging alternator 
Lubricating oil cooler   
Fuel filters, full flow paper element 
Fuel transfer pump, gear driven, plunger type 
Electronic type governor 
Jacket water pump, gear driven 
Lubricating oil filter, full flow paper element 
Lubricating oil pump, gear driven 
Exhaust dry manifold   
Radiator, blower fan, fan drive 
Manual shutoff 
24V DC electric starting motor 
STAND-BY 
780 kVA 
PRIME 
700 kVA 
MGS SERIES DIESEL ENGINE: MITSUBISHI S6R2-PTA-S