Operating Instructions and Parts Manual
www.chpower.com
Operation
DEFINITION OF TERMS
ON/OFF Switch ( I / O )
 - Push switch to 
the ON ( I ) position to turn compressor 
on . Push switch to the OFF ( O ) position 
to turn compressor off . This switch 
should be in the OFF ( O ) position 
when connecting / disconnecting power 
cord from electrical outlet or when 
changing tools .
Pressure Switch (located internally)- 
When the compressor is turned ON, 
this switch will shut compressor off 
automatically when tank pressure 
reaches maximum shut-off / cut-out 
pressure . If compressor remains on and 
air is depleted from tank, this switch 
will allow compressor to automatically 
restart at the restart / cut-in pressure .
Regulator - The regulator controls the 
amount of air pressure released at the 
hose outlet . Turning the regulator knob 
clockwise (to the right) will increase air 
pressure at the outlet . Turning the knob 
counter-clockwise (to the left) will lower 
air pressure to the outlet . Turning knob 
fully counter-clockwise will shut off flow 
of air completely .
Pressure Gauges - There are two 
gauges located next to the regulator . 
These gauges read air pressure in 
pounds per square inch (psi) . The 
gauge on the right shows pressure at 
the outlet . Make sure this gauge reads 
ZERO (by adjusting the regulator) 
BEFORE changing air tools or 
disconnecting hose from outlet . The 
gauge on the left shows pressure in the 
tank indicating compressor is building 
pressure properly . 
Figure 3 - ON/OFF switch
ON 
Position
OFF 
Position
ASME Safety valve - This valve 
automatically releases air if the tank 
pressure exceeds the preset maximum .
Handle - Designed to move the 
compressor .
Drain valve - This valve is located on 
the bottom of the tank . Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion .
Motor Protection - If the unit is over 
worked, a thermal limiter will shut unit 
off . If this happens, switch unit to OFF, 
wait 30 minutes to cool, turn ON again 
to resume work .
LUBRICATION
This is an oilless product and DOES NOT 
require lubrication to operate .
BEFORE FIRST STARTUP BREAK-IN 
PROCEDURE
(Complete this procedure before using 
compressor for the first time . Once  
completed, it is not necessary to repeat .)
1 .   Turn regulator knob fully clockwise 
(to the right) to open air flow .
2 .   Do not attach a hose or any other 
fitting to the compressor .
3 .   Turn ON/OFF switch to OFF position .
4 .   Plug in power cord .
5 .   Turn ON/OFF switch to ON position . 
Allow compressor to run for 5 
minutes .
6 .   Turn ON/OFF switch to OFF position .
7 .   Unplug power cord .
OPERATING PROCEDURE
1 .   Turn switch to OFF ( O ) position and 
plug in power cord .
2 .   Turn regulator knob 
counterclockwise to close air flow .
3 .   Turn switch to ON ( I ) position .
4 .   Compressor will build to maximum 
pressure and shut off .
5 .   With hose attached to outlet of 
compressor, attach tire chuck or 
other tool to open end of hose . 
Figure 4 - Drain valve
Figure 2 - Unit identification
ON/OFF 
Switch
Handle
Tank Drain Valve
Outlet 
Gauge
Regulator
Tank Gauge
Shroud
Tank
ASME Safety Valve
Air 
Outlet