Cisco Systems 2130 Manual De Usuario

Descargar
Página de 116
1-15
Cisco Application Deployment Engine (ADE) 2130 and 2140 Series Appliance Hardware Installation Guide
78-18579-02
Chapter 1      Introducing the Cisco Application Deployment Engine 2130 and 2140 Series Appliance
    Hardware Features
AC and DC Power Supplies
The Cisco ADE 2130 and 2140 Series appliance is equipped with either a 110-V or 220-V AC power 
supply or a –48-V to –60-V DC power supply (see locations 4 and 5 in 
Note
 shows an AC and DC power supply together for illustration purposes. Never 
install an AC or DC power supply in the same appliance.
Both power supplies are capable of operating in redundant mode. A power supply blank filler panel is 
used for the empty power supply slot and is supplied with an appliance without redundancy.
The power supply is rated for 600-W output capacity in full AC or DC input voltage.
Each power supply incorporates a single 40-mm fan for cooling, which also contributes to overall 
appliance cooling. The cooling air enters the power supply from the power distribution side. If airflow 
through the power supply is insufficient, the overtemperature protection circuits activate a shutdown 
before the temperature passes the maximum rated temperature.
Caution
To ensure proper cooling if only one power supply is installed, the power supply must be in the 
right-hand slot and the power supply blank filler panel must be in the left-hand slot. (See 
.)
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to 
hazardous voltages and currents inside the chassis; they contain electromagnetic interference 
(EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. 
Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. 
Statement 1029
To maintain hot-swap capability, ensure that an active power supply is in both power supply slots before 
replacing (hot-swapping) a power supply. Check the power supply LED to determine which power 
supply module has failed. (See location 2 in 
 for either AC or DC power supply.)
Warning
Never install an AC power module and a DC power module in the same chassis. Statement 1050
AC Power Supply Input
A single receptacle is provided at the rear of the AC power supply for AC input.
DC Power Supply Input
The Cisco ADE 2130 and 2140 Series appliance uses a small, two-wire DC power Molex terminal block 
connector for input to the power supply.
With the connector installed in the appliance, the pins from top to bottom of the DC power terminal block 
are labeled – and +, respectively. 
 lists the pinout configuration for the connector.