Command Reference
601356 Rev A
Command Reference
2-133
Commands
Return Codes
0  -  The 
vsqrymount
 command is successfully processed.
-1 - An error is detected by either the CLI software or the 
API software.
-I
Command options are first read from the 
command line. VolServ then reads any 
options contained in the 
stdin
 file.
-h
Requests help for the entered command. 
When the Help option is specified, no 
command line processing is performed.
An exit code of 0 is returned to the client when 
the Help option is specified.
-H 
hostname
Host name of the VolServ server.
The default host name is the host name of the 
computer where the CLI command is run.
-
priority
Default value is 
15.
The execution priority of the entered 
command. Assignable priority values are 
restricted to a range from 1 (highest) to 32 
(lowest) inclusive.
-R 
retries
Default value is 
3.
Number of retries the CLI software attempts if 
a time-out is returned by the API software.
-T 
timeout
Default value is 
120 seconds.
Amount of time (in seconds) the API software 
waits for status from VolServ before returning 
a time-out to the CLI software. Total wait time 
for a command is (retries plus 1) multiplied by 
time-out value.
-V 
prognum
Default value is 
300016.
RPC program number for VolServ.
Parameter
Description