Mentor v8.6_4 Manual De Usuario

Descargar
Página de 831
Command Dictionary
Report Bus Data
FastScan and FlexTest Reference Manual, V8.6_4
2-271
ZAbort — (FastScan Only) A literal that displays the bus data for the
buses that abort the E11 design rule check.
Examples
The following example displays the information on a specific bus gate—an
inverter (INV):
report bus data 31
/FA1/XOR1/OUT/ (31)Handling=pass type=strong #Drivers=2 (INV)
Bus Drivers:  30(SW) 28(SW)
FastScan Example
The following FastScan example first enables access to the static learning data,
then displays both the learned information and the bus data on a specific bus gate,
again, an inverter (INV):
set learn report on
report bus data 31
/FA1/XOR1/OUT/ (31)Handling=pass type=strong #Drivers=2 (INV)
Learn Data :  poss_X=no, poss_Z=no, poss_mult_drivers_on=no
Bus Drivers:  30(SW) 28(SW)
Related Commands