Mentor v8.6_4 Manual De Usuario
![Mentor](https://files.manualsbrain.com/attachments/d00bf2d59f41402c217e360dd99f091d0cf5f9c4/common/fit/150/50/827c18e944ba329c56dd7a5b3e61d17255e9ede4423201f9105d21fe5532/brand_logo.png)
Command Dictionary
Report Nonscan Cells
FastScan and FlexTest Reference Manual, V8.6_4
2-341
Report Nonscan Cells
Tools Supported: FastScan and FlexTest
Scope: Atpg, Fault, and Good modes
Usage
For FastScan
REPort NOnscan Cells [-All | -TIE0 | -TIE1 | -TIEX | -TLatch | -Clock_sequential
| -INIT0 | -INIT1]
For FlexTest
REPort NOnscan Cells [-All | -INITX | -TIE0 | -TIE1 | -Hold | -Data_capture]
Description
Displays the non-scan cells whose model type you specify.
The Report Nonscan Cells command displays the instance name, gate number,
and model type of the non-scan cells that you specify. The tool assigns a model
type to the non-scan cells during the Design Rules Check (DRC) in order to model
non-scan memory behavior more exactly.
and model type of the non-scan cells that you specify. The tool assigns a model
type to the non-scan cells during the Design Rules Check (DRC) in order to model
non-scan memory behavior more exactly.
During scan loading, scan clocks can affect non-scan memory elements. The
worst case is to assume that all non-scan memory elements will have an unknown
state right after scan loading, which makes some faults difficult to test. Therefore,
the tool assigns an appropriate model type to the non-scan cells, which sets them
to known values. The argument descriptions that follow describe the conditions
that the tool uses to make the various model type assignments.
worst case is to assume that all non-scan memory elements will have an unknown
state right after scan loading, which makes some faults difficult to test. Therefore,
the tool assigns an appropriate model type to the non-scan cells, which sets them
to known values. The argument descriptions that follow describe the conditions
that the tool uses to make the various model type assignments.
Arguments
•
-All
An optional switch that displays all non-scan cells. This is the default.
•
-INITX (FlexTest Only)
An optional switch that displays the non-scan cells which FlexTest initializes
to X after each loading.
to X after each loading.