Command Dictionary
Set Multiple Load
FastScan and FlexTest Reference Manual, V8.6_4
2-527
Set Multiple Load
Tools supported: Fastscan
Scope: All modes
Usage
SET MUltiple Load ON | OFf
Description
Specifies how the tool handles multiple scan loads.
The Set Multiple Load command specifies how the tool handles multiple scan
loads. It supports patterns containing more than one scan load operation. You can
use this command to take advantage of non-scan sequential cells which are
capable of retaining state through a scan load operation. The multiple load
functionality is an extension to clock sequential ATPG.
When multiple load patterns are in the pattern set, an additional line is output in
the statistics report. This extra line indicates the number of multiple load patterns
in the current pattern set. For example:
Statistics report
-------------------------------------------
                          #faults   #faults
fault class               (coll.)   (total)
-----------------------   -------   -------
FU (full)                    150       198
-----------------------   -------   -------
DS (det_simulation)           71       105
DI (det_implication)          65        79
PT (posdet_testable)          14        14
-----------------------   -------   -------
test_coverage              95.33%    96.46%
fault_coverage             95.33%    96.46%
atpg_effectiveness         95.33%    96.46%
-------------------------------------------
#test_patterns                          18
    #clock_sequential_patterns           3
    #multiple_load_patterns             15
#simulated_patterns                     64
CPU_time (secs)                        0.3
-------------------------------------------