Cisco Systems 15454M6DC Manual De Usuario
7-2
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 7 Card Provisioning
Provisioning Electrical Cards
7.2 Provisioning Electrical Cards
The ONS 15454 electrical cards (DS1-14, DS1N-14, DS3-12, DS3N-12, DS3E1-12, DS3EN-12,
DS3XM-6, and EC1-12) are pre-provisioned with settings that you can modify to manage transmission
quality. When you open a card in CTC and select the Provisioning tab, the following subtabs are
commonly displayed:
DS3XM-6, and EC1-12) are pre-provisioned with settings that you can modify to manage transmission
quality. When you open a card in CTC and select the Provisioning tab, the following subtabs are
commonly displayed:
•
Line—Sets line setup parameters, such as line coding and line length. This is also where you put
ports in and out of service.
ports in and out of service.
•
Line Threshold—Sets the line-level PM thresholds.
•
Elect Path Threshold—Sets the path-level PM thresholds for electrical (DS-3/DS-1) traffic.
•
SONET Threshold—Sets the path-level PM thresholds for (STS/VT1.5) traffic.
•
Alarming—Sets alarm profiles for individual ports and suppresses alarms. See
for information about alarm profiles and alarm suppression.
provides an overview of DS-1, DS-3, DS3E, and DS3XM parameters (an X means the item is
Table 7-1
DS-N Card Provisioning Overview
Subtab
Provisioning Item
DS1-14/
DS1N-14
DS1N-14
DS3-12/
DS3N-12
DS3N-12
DS3E1-12/
DS3EN-12
DS3EN-12
DS3XM-6
Line
Port #
X
X
X
X
Port Name
X
X
X
X
Line Type
X
X
X
Detected Line Type
X
Line Coding
X
X
X
Line Length
X
X
X
X
Status
X
X
X
X
Line Threshold
Port
X
X
X
X
CV
X
X
X
X
ES
X
X
X
X
SES
X
X
X
X
LOSS
X
X
X
Elect Path
Port
X
X
X
CV
X
X
ES
X
X
X
SES
X
X
X
SAS
X
X
X
AIS
X
X
X
UAS
X
X
X