Cisco Systems 15454M6DC Manual De Usuario

Descargar
Página de 458
 
8-22
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 8      Performance Monitoring
Performance Monitoring for Electrical Cards
8.5.3  DS3 and DS3N Card Performance Monitoring Parameters
 shows the signal types that support far-end PMs. 
 shows where overhead bytes 
detected on the ASICs produce performance monitoring parameters for the DS3 and DS3N cards.
Figure 8-15 Monitored signal types for the DS3 and DS3N cards
Note
The XX in the illustration above represents all PMs listed below with the given prefix and/or suffix.
Table 8-12 Far-End VT Path PMs for the DS1 Card
Parameter
Definition
CV-V
Far-End VT Path Coding Violations (CV-VFE) is a count of the number 
of BIP errors detected by the far-end VT path terminating equipment 
(PTE) and reported back to the near-end VT PTE using the REI-V 
indication in the VT path overhead. Only one BIP error can be indicated 
per VT superframe using the REI-V bit. The current CV-VFE second 
register is incremented for each BIP error indicated by the incoming 
REI-V.
ES-V
Far-End VT Path Errored Seconds (ES-VFE) is a count of the seconds 
when at least one VT path BIP error was reported by the far-end VT PTE, 
or a one-bit RDI-V defect was present.
SES-V
Far-End VT Path Severely Errored Seconds (SES-VFE) is a count of the 
seconds when K (600) or more VT path BIP errors were reported by the 
far-end VT PTE or a one-bit RDI-V defect was present.
UAS-V
Far-End VT Path Unavailable Seconds (UAS-VFE) is a count of the 
seconds when the VT path is unavailable at the far-end. A VT path is 
unavailable at the far-end when ten consecutive seconds occur that qualify 
as SES-VFEs.
55311
ONS 15454
DS3
OC48
Fiber
Near End
DS3 Signal
DS3 Path (DS3 XX) Far End PMs Not Supported
ONS 15454
DS3
OC48
Far End
DS3 Signal
STS Path (STS XX-P) Far End PMs Not Supported