GEH-6385  Reference and Troubleshooting, 2300 V Drives
Chapter 3  Paramters/Functions  
••••
  3-83
 
Function outputs
Variable
Description
Run request
The request to run the drive.  The details of the logic which
forms this signal is shown in the sequencer diagrams.
Jog request
The request to run the drive at the appropriate jog reference
(see Local Speed Reference or Remote Speed Reference for
details on speed reference). The details of the logic which
forms this signal is shown in the sequencer diagrams.
Run command
Internal sequencer command formed from Run requestJog
request and the Ready to run permissive string.
Run active
Drive is running in response to Run request.
Jog active
Drive is running in response to Jog request.
Related diagrams
  General Sequencing #2 (GenSeq_2)
Flux Commands
 A flux command (initiated by Full flux command or Standby command) will:
  Enable bridge power
  Flux the drive
  Disable the torque reference (if enabled)
 
Function inputs
Parameter
Description
Full flux req sel
Selects the variable that requests the drive to be pre-fluxed
and waiting for a run command.  This input is only active in
“Remote mode”.  It is treated as a +/- edge-triggered input.
If the drive is using a Tachless mode motor control and Flying
restart
 is set to Locked shaft restart, this input will request a
Standby command.
Variable
Description
Full flux req, lan
Requests the drive to be pre-fluxed from the LAN if LAN
commands OK
 is True.  This input is only active in “Remote
mode”.  It is treated as a +/- edge-triggered input.
(Also see LAN Signal Map.)