Recovering from Problems
6-7
Verifying Critical
Parameters
Verify that the settings of the following critical parameters match those 
of the ATM switch to which the ATM Backbone SwitchModule is 
connected:
UNI version (default is 3.0)
LEARP Quiet Time (default is 5 seconds)
Configuration mode (LEC 1 default is Auto, default for other LECs is 
Manual)
Interface mode (LEC 1 default is Enabled, default for other LECs is 
Disabled)
ELAN Name (LEC 1 default is Admin, default for other LECs None)
Vbridge assignment (LEC 1 default is vbridge 1, default for other 
LECs is Unassigned)
See the CoreBuilder 5000 ATM Backbone SwitchModule Command 
Reference for more information on these parameters.
Verifying ATM OC-3
Card Functions
Use the following procedure to verify each of the following ATM OC-3 
card functions:
With the OC-3 fiber cables attached, verify that the Alarm LED of the 
ATM OC-3 card is illuminated green.
If the Alarm LED is illuminated green, reverse the fiber optic cable 
connections to the ATM OC-3 card and reverify the Alarm LED.
Use the following command to check the additional port status 
indicators for the ATM OC-3 card:
CB5000> show port <slot.phy_num>
Verify that the display lists the following indicators:
Status for the (PHY) port is OK
Mode for the (PHY) port is Enabled