Black Box 3600 Manual De Usuario

Descargar
Página de 270
Status Registers
10-14
Modem 3600
Remote Configuration Guard Time   S42
Select the remote configuration guard time  (0-255) in 20 ms intervals. 
The default is 50 (1 sec).
S43
Reserved
XON Character from DTE   S44
Select the XON character (0-127) to be sent from the DTE. The default 
value is ASCII 17.
XOFF Character from DTE   S45
Select the XOFF character (0-127) to be sent from the DTE. The default 
value is ASCII 19.
S46-48
Reserved
XON Character to DTE   S49
Select the XON character (0-127) to be sent to the DTE. The default 
value is ASCII 17.
XOFF Character to DTE   S50
Select the XOFF character (0-127) to be sent to the DTE. The default 
value is ASCII 19.
Dial Line Transmit Level   S51
The S51 register selects dial line transmit level from -9 to -30 dBm in 1 
dBm increments. The default value is 10.
Bit
Value
Command Description
4-0
0 to 30 *TDn (n=9 
to 30)
Transmit level in dBm (-9 through -30 
dBm) 
7-5
--
--
Reserved