V.25 bis Autodialer
11-2
Modem 3600
Autodialer Command Strings and Parameters
Most command strings for the autodialer include two parts: the 
command itself and the parameters that follow. For the purposes of this 
chapter, parameters can be telephone numbers or anything appropriate 
to V.25 bis as described in the following text. Parameters are separated 
by semicolons. 
For example: 
PRN a; nnn . . . n 
where a= the phone number address in memory and nnn...n= the 
phone number. The a and the nnn...n are both parameters. Not all 
commands have parameters. For example the CIC command has no 
parameter.
Software Guidelines
• An indicator enclosed in less than/greater than signs represents a 
specific character in the appropriate character set, ASCII or 
EBCDIC.
<sp> - space
• Each response below is considered an individual message by V.25 
bis conventions.  For example, a dial command with intermediate 
call
 progress enabled (BISYNC mode ASCII/EBCDIC character 
set) is:
From computer To computer
<sy><sy><stx>CRN<sp>(205)555-0124<etx> <sy><sy><stx>VAL<etb>
• V.25 bis commands can be in one of these data formats:
ASYNC
BISYNC
SDLC
NRZ
SDLC
NRZI
in ASCII or EBCDIC
Access these formats using:
&M
Asynchronous dial/asynchronous data
&M1
Asynchronous dial/synchronous data
&M2
Dials stored number when DTR off/on transition is detected/sync data