Black Box 3600 MODEM Manual De Usuario

Descargar
Página de 270
V.25 bis Autodialer
11-12
Modem 3600
• An out-of-range value for a particular option is specified In the 
above example, if the fourth value in the option string is 
undefined or out-of-range for option 13 in a certain modem (and 
no other error conditions apply), options 10 through 12 would be 
changed as specified in the command message. The next option to 
be changed would be option 13. The modem would then detect 
that the value is undefined or out-of-range for that option, stop 
execution of the command, and return an 
INVPV013
 message 
Options 10 through 12 would still be changed as commanded; 
options 13 and 14 would be unchanged.
Save Current Settings   PRK
PRK
 saves the current option settings. 
Responses:
VALValid command received.  Transmitted on receiving an error-
free command with no transmission error such as a parity
error. Confirmation is sent before the command is executed.
INVCUInvalid command - command unknown.
    Example: TRK
INVMSInvalid command - message syntax error.
     Examples:PRK;0 
PRK Q
Restore Factory Settings   PRP
 n
PRP n
 restores current option settings to factory option set n where n is 
a 1 digit decimal number. 
Note
Restoring a factory option set other than factory option 9 
disables the V.25 synchronous dialer.
If no parameter follows the command, the modem automatically selects 
factory option set 1.
Responses:
VALValid command received.  Transmitted on receiving an error-
free command with no transmission error such as a parity
error.  This confirmation is sent before the command is executed.