Black Box 3600 MODEM Manual De Usuario

Descargar
Página de 270
Hardware Options
D-2
Modem 3600
Modem and Telephone Line Check
Part I
1) Configure the modem for LOCAL ANALOG LOOP WITH 
TEST PATTERN. This terminates the local modem telephone 
lines into 600 ohms and connects the local modem transmit 
output amplifier back to its own receiver through the AGC. 
Transmit input data from the terminal is inhibited and is 
substituted with a V.52 test pattern.
2) This test checks operation of the local modem modulator and 
demodulator circuitry and should be attempted at both local and 
remote sites if operators are available.
3) When random errors are present, the TEST PATTERN ERRORS 
display counts receive errors.
4) If the circuitry is working properly, the front panel indicators 
show the following:    
5) Configure the modem for LOCAL ANALOG LOOP to switch 
the transmitter back to its normal data input.
6) If the transmit data input is in a mark hold condition, both the TD 
and RD indicators should remain off.
7) If the transmit data input is in a space hold condition, both the 
TD and RD indicators should come on. All other indicators 
should remain the same.
8)  If the indicators are correct, the modem is probably operating 
correctly.
9)  If the preceding tests were not successful, call Technical