Black Box 3600 MODEM Manual De Usuario

Descargar
Página de 270
AT Commands
Modem 3600
5-27
Synchronous Transmit Clock Source   &X
The &X commands select internal, external, or receive clock as the 
transmit clock source. 
V.34 Rate Selection Thresholds   *TH
The *TH commands sets the V.34 rate selection thresholds. The V.34 
modulation dynamically selects the optimum bit rate to run, based on 
line quality. 
V.34 Asymmetric Bit Rates   *AS
The *AS command enables or disables the V.34 asymmetric bit rate 
capability. This feature allows the modem to run different bit rates on 
the receiver and transmitter. 
Modulation *MM
The *MM command sets the current modulation type to use when 
attempting to make a connection. Using this command automatically 
selects the maximum DCE speed (%B) for the selected modulation. 
Command
Operation
&X
Internal clock
&X1
External clock
&X2
Receive clock
Command
Operation
*TH
Low V.34 threshold (10
- 6
 BER)
*TH1
Medium V.34 threshold (10
- 4 
BER)
*TH2
High V.34 threshold (10
- 2 
BER) 
Command
Operation
*AS
Disable V.34 asymmetric bit rates
*AS1
Enable V.34 asymmetric bit rates
Command
Operation
*MM
Automode (typically used on dial line)
*MM1
V.21
*MM2
B103
*MM3
Reserved
*MM4
B212A