Connect Tech Blue Heat/PCI PCI Serial Communications Manual De Usuario

Descargar
Página de 47
Blue Heat/PCI User’s Manual, Connect Tech Inc. 
 
Revision 0.11  
 
40 
 
Appendix D: 20mA Current Loop Line Interface 
Blue Heat/PCI 20mA CL 
The Blue Heat/PCI CL offers a 20mA Current Loop active or passive electrical interface.  For 
each port there is an optically isolated receiver, an optically isolated transmitter and a 20mA 
current source.  Optical isolation is functional in passive mode only.  See 
 for the 
schematic of the 20mA Current Loop module. 
 
Note: The current source uses a compliance voltage of 11 or 22 volts, and the transmitter will 
withstand a 27 volt drop.  Please refer to the Hewlett Packard Optoelectronics Manual/Catalogue 
for a complete description of HPCL 4100 and HPCL 4200 specifications. 
 
Figure 15: Partial schematic: Blue Heat/PCI 20mA CL 
 
 
51 Ohm 
VF = 1.5V 
-12V 
RxD SRC 
+12V 
RxD RET 
2N2907A 
22K 
51 Ohm
VF = 1.5V
RxD SRC
+12V
RxD RET
2N2907A
22K
+5V
+5V
 
+5V
3  TxD +
 
TxD  6
 
4  TxD -
 
HCPL 
4100
 
5
 
8
 
HCPL
4200
8
5
6
RxD  7
1  RxD +
2  RxD -
CTS
DCD
RI
DSR
300 mA 
J1, J2, J3, J4, J5, J6, J7, J8
(must jumper – see Current 
Source/Voltage Selection) 
 
 
To implement an optically isolated passive interface, wire the transmitter and the receiver, while 
leaving the current sources unconnected.  An external current source is required to implement a 
passive interface. 
 
To implement an active interface, connect a 20mA current source in series with the transmitter 
and another 20mA current source in series with the receiver.  Please refer to 
for a 
20mA Current Loop cable wiring configuration between one port of a Blue Heat/PCI CL adapter 
and another port of a Blue Heat/PCI CL adapter.  This example shows wiring for both active and 
passive modes