Connect Tech Blue Heat/PCI PCI Serial Communications Manual De Usuario

Descargar
Página de 47
Blue Heat/PCI User’s Manual, Connect Tech Inc. 
 
Revision 0.11  
 
44 
 
Appendix E: Blue Heat/PCI PTM model 
Blue Heat/PCI PTM Adapter 
The Blue Heat/PCI Pass Through Mux (PTM) adapter offers two asynchronous RS-232 serial 
ports with Monitor Pass Through and Intercept Pass Through capabilities.  In Monitor mode the 
Blue Heat/PCI PTM adapter allows you to monitor and pass through the data from a device 
connected to one serial port to a device connected to the other serial port.  This pass through 
connection is maintained even if the power or software fails in the computer hosting the Blue 
Heat/PCI PTM, but without monitoring capabilities. 
 
In Intercept mode you can monitor, process and then pass through the data from a device 
connected to one serial port to a device connected to the other serial port.  Once again this pass 
through connection is maintained even if the power or software fails, but without 
monitoring/processing capabilities. 
 
Features 
ƒ
 
Two, asynchronous RS-232 serial ports 
ƒ
 
Supports data communications speeds up to 921 Kbps 
ƒ
 
A 16C2850 UART controls each port providing 128 bytes of TxD/RxD FIFO buffers 
ƒ
 
Independent port configuration with baud rates from 50 bps to 921 Kbps; data bits of 5, 6, 7 
or 8; stop bits of 1, 1.5, or 2, and odd, even, or stick parity 
ƒ
 
Monitor Pass Through Mode: you can monitor and pass through data from a device on one 
serial port to a device on the other serial port.  If power or software fails the serial port 
connections will default to direct pass through 
ƒ
 
Intercept Pass Through Mode: you can monitor, process and pass through data from a device 
on one serial port to a device on the other serial port. If power or software fails the serial port 
connections will default to direct pass through 
ƒ
 
Utilizes robust high quality Telecom DPDT relays to achieve direct pass through when power 
fails 
ƒ
 
Onboard DB-9 connectors 
ƒ
 
No DIP switches or jumpers to set – full Plug and Play 
 
Figure 17: Blue Heat/PCI PTM adapter 
 
Female DB-9
Port 2
PCI Bridge
16C2850 dual UART
CPLD
Blue Heat-2/PCI PTM adapter 
Male DB-9 
Port 1 
DPDT Relays