If a particular Radio Link Module has stopped responding to normal bridging 
requests, you can reboot (reset) the Access Point RLM. You can reboot 
RLMs either manually on-the-spot or remotely.
Upon reboot, the Radio Link Module will run the start-up diagnostics and 
start bridging operation using the configuration parameters as they were 
stored in the RLM prior to the reboot. For “out-of-the-box” RLMs, these 
parameters will be as identified in 
% 0DQXDO5HERRW
To reboot the RLM manually on-the-spot proceed as follows:
1.
Remove the cover of the Radio Link Module (see the Manual “Industrial 
Ethernet Wireless LAN, Radio Link Module RLM” on IWL-CD that came 
with your RLM, for assistance if needed).
2. Locate the two small holes on the bottom of the processor module, 
marked “Reset”  and “Reload” as pictured in 
.