28
Startup
Activation of the  PD_IN reset signal on 
the power supply connection
The POWERDOWN line on the GSM 
module is connected to the watchdog input 
pin of the power supply ASIC, which can 
only be switched off by changing the 
watchdog condition. To do this, the PD_IN 
Terminal reset line is active (high) for at least 
3.5s. This results in immediate, "hard" 
disconnection, with the TC35 Terminal 
unable to sign off correctly from the base 
station in the STANDBY and TALK operating 
states .
In the case of this hardware shutdown, the 
software is no longer able to respond before 
the voltage is switched off. This corresponds 
to a direct, unannounced disconnection of 
the operating voltage. In the application you 
can switch off or reset the module without 
interrupting the input voltage supply.