Hardware Information
3-138
 G24-L AT Commands Reference Manual
April 15, 2008
&D, Circuit 108 Behavior
This command determines how the G24-L responds when the DTR (Data Terminal Ready) status 
is changed from ON to OFF during the online data state. The DTR is an input line that indicates 
that the terminal is ready.
The DTR line must be active (low) in order for the G24-L to recognize the terminal. This signal is 
raised by the terminal when a process activates the serial port. If the DTR is not used by the 
application, it should connect this line to ground (DTR active). The default value is active (low).
The following table shows the &D parameters.
Example
AT&D?
&D: 2
OK
AT&D1
OK
Command Type
Syntax
Response/Action
Set
AT&D<param>
OK
Read
AT&D?
&D:<param>
Test
AT&D=?
&D:(list of supported <param>s)
Table 3-89: &D Parameters
<Parameter>
Description
<param>
The G24-L’s reaction when the DTR status is changed from ON to OFF.
In CSD calls:
0,4
Ignores DTR changes
1
Switches the CSD call to asynchronous command mode (the call remains 
connected)
2,3
Disconnects the call and returns to the command mode
In GPRS calls:
0,4
Ignores DTR changes
1-3
Deactivates the GPRS and returns to command mode
The default value is 2.