Technical Data 
34
313855H
Technical Data
 
Input Contact 
Power Source DC - model 24B591
9 - 30 VDC
Power Source AC - model 24B596
100 VAC to 240 VAC - 50/60 Hz
Power consumption
24 Watts
Cycle Pressure Control Input (optional)
Normally open pressure or cycle switch
Machine Count Control Input (optional)
Machine count control switch
Lubrication level (optional)
Normally open level switch, closes upon low level
Remote Manual Run Input 
Normally open remote manual run switch
Outputs
Pump control 
Pump Control Voltage = Power Source
Voltage
Power Source
Max Switching Voltage
250 VAC, 100 VDC
Max Switching Current
10 A (AC), 5A (DC)
Minimum Switching Capacity
100 mA @ 5 VDC
Low Level Alarm, normally open (optional)
Voltage
Power Source
Max Switching Voltage
250 VAC, 30 VDC
Max Switching Current
5A (AC), 5A (DC)
Minimum Switching Capacity
100 mA @ 5 VDC
Auxiliary Alarm, normally open (optional)
Voltage
Power Source
Max Switching Voltage
250 VAC, 30 VDC
Max Switching Current
5A (AC), 5A (DC)
Minimum Switching Capacity
100 mA @5 VDC
Status OK, normally open (optional)
Voltage-free Contact
Voltage
Power Source
Max Switching Voltage
250 VAC, 100 VDC
Max Switching Current
10 A (AC), 5A (DC)
Minimum Switching Capacity
100 mA @ 5 VDC
Protection grade
IP69K
Enclosure Material
Fiberglass reinforced polyester
Membrane Material
Polyester
Bushing
Ethylene Propylene Diene Monemer Rubber (EDPM)
Operating temperature range
- 40°F to 145°F (- 40°C to 63°C)
Storage Temperature
- 13°F to 145°F (- 25°C to 63°C)