Cisco Systems Cisco IOS XR Manual De Usuario

Descargar
Página de 222
3-25
Cisco IOS XR Getting Started Guide
OL-10957-02
Chapter 3      Bringing Up the Cisco IOS XR Software on a Multishelf System
Integrated Switch System
SUMMARY STEPS
1.
admin
2.
clear controller switch errdisable {port {FE | GE} {0 | 1}} {location node-id}}
3.
clear controller switch inter-rack {errdisable {ports {number | all} | statistics {all | ports 
number}} {location node-id}
DETAILED STEPS
Verifying the Connections of the Integrated Switch Control Network
This section presents how to verify the connections and operations of the integrated switch control 
network with 22-port SCGEs:
Verifying the Control Ethernet Connection
To verify the control Ethernet connection on intra-rack switches, use the show controllers switch 
command with the ports and location keywords, as shown in the following example:
RP/0/RP0/CPU0:router(admin)# show controllers switch 0 ports location 0/rp0/Cpu0
FE Port  0 : Up, STP State : FORWARDING (Connects to - F0/SC0)
 FE Port  1 : Up, STP State : FORWARDING (Connects to - F0/SC1)
Command or Action
Purpose
Step 1
admin
Example:
RP/0/RP0/CPU0:router# admin
Places the router in administration EXEC mode.
Step 2
clear controller switch errdisable
 {port {FE | GE
{0 | 1}} {location node-id}}
Example:
RP/0/RP0/CPU0:router(admin)# clear controller switch 
errdisable port GE 1 location f0/sc0/cpu0
Clears the err-disable state of the switch port for the 
RP ports.
Use the FE keyword to display the ports for Fast 
Ethernet (FE).
Use the GE keyword to display the ports for 
Gigabit Ethernet (GE).
Step 3
clear controller switch inter-rack
 {errdisable 
{ports {
number
 | all} | statistics {all | ports 
number
}} {location 
node-id
}
Example:
RP/0/RP0/CPU0:router(admin)# clear controller switch 
inter-rack statistics all location f0/sc0/cpu0
Clears the err-disable state of the inter-rack switch 
ports on the 22-port SCGE.