APPENDIX A.  DIMENSIONS FOR MOUNTING 
 
MOUNTING 
 
The bottom of the unit is shown in Figure 2-1 and 2-2.  The IntelliStripe 380 may be mounted in 
one of three ways:  1) foot pads, 2) set of mounting holes for 3 screws (4 x 40), and 3) 4 lock-in-
place slots.   
 
The mounting dimensions of the 3 screw holes and the 4 lock-in-place slots are shown in Figure 
A-1. 
 
Footpad Mounting 
 
The footpads are mounted at the factory if it is the default.  Simply place the unit on a level 
surface with approximately 4 inches clearance from obstructions at the front of the unit for card 
clearance.  Leave enough room at the rear of the unit for cable clearance.  
 
Mounting Hole Screws 
 
Locate the 3 screw holes (4 x 40 screws) shown in Figure 2-1.  The length of the screws depends 
on the thickness of the mounting surface.  Drill 3 holes in the mounting surface that match the set 
of screw holes.  The screws are mounted from under the mounting surface and into the bottom of 
the IntelliStripe 380.  
 
Lock-in-place-slots  
 
The overall dimensions of the unit are shown in Figure A-2. 
 
The MagTek Mounting Plate, Figures A-3 and A-4, show the use of the Lock-in-place slots 
(Refer also to Figures 2-2).  In the example the holes are placed over mounted inserts and the 
unit is pulled the length of the slots forcing the thickest part of the plate to lock the unit in place.   
The value and tolerances of the plate at the end of the slots are .087” ±.005” (Figure A1), and the 
value and tolerances of the “stem” of the mushroom-shaped inserts are .085” ±.005” as shown in 
Figure A-4. 
 
Flange 
 
The flange shown in Figure 2-2 may be used to screw the unit to the mounting surface using a #4 
screw.  It can be used with any mounting configuration.