2 - Installation
Preparing for Installation
DX40 Serial Device Router Installation Guide
10
2.1.3
Wiring and Grounding Guidelines
The DX40 requires several different types of connectors, cables, and wires. 
Requirements and recommendations are listed below:
Fiber
The fiber cables connected to the DX40 must be:
• non-dispersion shifted, single mode (SM)
or 
• multi-mode (MM) fiber cables defined by the Telcordia 
Technologies General Recommendation 20-CORE 
standard 
and
• terminated with LC connectors (see 
.)
Grounding
The primary ground stud located on the top of the chassis must 
be used to connect to an approved ground with a wire meeting 
the following criteria: 
• 14 AWG (minimum)
• a maximum of five feet in length
• terminated on the ground lug side with a #6 ring lug
Facility Power
The facility power cabling attached to the DX40 chassis must 
meet the following criteria:
• cabling constructed using 14 AWG stranded wire
• cable firmly attached to the terminal holes of the 
non-polarized power unit, as illustrated in 
.
• cable routed and strain relieved to the chassis according to 
good wiring practices
Copper
Copper I/O cables and connectors must be shielded.