Graco 312353B Manual De Usuario

Descargar
Página de 74
System Administrator Screens
312353B
41
Tank Shape Screen
Vertical Tank Geometry (F
IG
. 75)
Vertical tanks use the tank capacity to calculate tank vol-
ume. Obround and cylindrical tanks use the tank dimen-
sions to calculate tank volume.
Verifying Capacity for Obround and Cylindrical 
Tanks (F
IG
. 76 and F
IG
. 77)
After the obround or cylindrical tank setup information 
has been completed, it may be necessary to modify the 
tank manufacture’s published gal/liter capacity that was 
entered in F
IG
. 74, (page 40). (In some cases the actual 
volume of the tank may exceed the manufacture’s pub-
lished capacity.) 
To verify this, once the TLM has been 
programmed:
1.
Stand the TLM upright on a flat smooth surface, 
press the blue button and record the volume. The 
volume shown on the PC tank setting screen should 
match the volume initially entered. If it does nothing 
further needs to be done.
2.
If the reading does not match, modify the tank 
capacity in F
IG
. 74, (page 40) to match the TLM 
reading taken on the flat smooth surface.
Vertical Tank
F
IG
. 75 Vertical Tank
Obround Tank
F
IG
. 76 Obround Tank
Cylindrical Tank
F