Siemens D410 Manual De Usuario
Commissioning (software)
4.3 Configuring the system in online mode
D410
Commissioning Manual, 08/2008 Edition
Commissioning Manual, 08/2008 Edition
75
4.3.3
Starting automatic configuration
Prerequisites
● You activated the online connection to SINAMICS Integrated.
● You have not yet configured any drive objects.
● The default settings of SINAMICS Integrated were activated.
● You have not yet configured any drive objects.
● The default settings of SINAMICS Integrated were activated.
Right-click SINAMICS Integrated" and select the "Target device" > "Restore defaults"
command from the shortcut menu in SIMOTION SCOUT in order to restore the factory
settings.
Procedure
1. Open the "Automatic Configuration" dialog box by selecting the "SINAMICS_Integrated >
Automatic configuration" command in the Project Navigator.
Figure 4-12 Starting automatic configuration
2. Click "Start automatic configuration".
The "Drive Object Type" dialog box opens.
Figure 4-13 Selecting the drive object type